This software is for users who wish to install the GX-A/GF-A balance in an automated weighing system and adjust its response settings beyond the standard settings.
Impact shock detection (ISD) providing feedback to prevent damage to the weight sensor*1 Electronically controlled load (ECL) that enables precision management without using an external weight*1 Flow rate display (FRD) that makes calculating and recording flow rates easier and more accurate*2 IP65 dust and waterproof (GX-AWP/GF-AWP) Smart super hybrid sensor (Smart SHS) that realizes fast stabilization, long-term durability and low cost of ownership Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection Cushioning under the weighing pan to mitigate impact shocks significantly Protection against vertical and transverse static overloading Flow rate comparator that indicates whether the flow rate is within the designated limits Tare memory function that saves the tare value in non-volatile memory Built-in fanless ionizer with Quick Ion® technology and external IR switch (GX-AE) Large and detachable, antistatic glass breeze break (0.0001 g models) Retractable doors that fold into the back, requiring no extra space at the rear Automatic self calibration in response to temperature changes or according to set schedules (GX-AE/GX-A/GX-AWP) Automatic minimum weight calculation with either ECL or an actual, external weight Alert function to ensure that the measured quantity is not smaller than the set minimum weight Selectable response characteristics for trading faster weighing speed for higher display stability or vice versa Large, front-mounted spirit level with LED illumination Easy-to-adjust leveling feet with thumbwheels User access control (UAC) that password-protects the balance from misuse GLP/GMP/GCP/ISO compliant output to meet documentation requirements Universal Flexi Coms (UFC) to customize printout content and layout*3 Gross/Net/Tare output Data memory function to save weighing results, calibration results and unit masses to be used in counting mode in the device itself Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function Percent mode function for target weighing or checking sample variation Animal weighing (average & hold) function for weighing moving objects Statistical calculation function (SCF) to facilitate the analysis of measurements Five-level comparator function with buzzer Auto power ON and OFF functions Density determination function (optional density determination kits available for the 0.0001/0.001 g models) Underhook for weighing a magnetic material as well as measuring density
*1 Patented
*2 For graphing weight and flow rate changes in real time, download WinCT-FRD here
*3 For editing and sending UFC setting commands, download WinCT-UFC here
Videos
Demonstration Videos - Introducing Various Functions of the GX-A/GF-A Series
Clip 1: ISD Function
Clip 2: ECL Function
Clip 3: FRD Function
Introducing Windows UFC Setting Tools, "WinCT-UFC"
External Input/Output
RS-232C interface (standard)
Quick/bi-directional USB interface*4 (standard)
2nd RS-232C interface (optional)
Comparator relay output/buzzer/external key input interface (optional)
Analog (0-1/0.2-1 V) output interface (optional)
Ethernet (TCP/IP) interface (optional)
External key input interface + the AX-SW137-PRINT foot switch (optional)
External key input interface + the AX-SW137-REZERO foot switch (optional)
External key input interface + the AX-T-314A-S plug (optional)
USB host interface (optional)
External IR switch (optional)
*4 Users can toggle between the Quick USB mode (plug-and-play with weighing data output to a PC only) and the Virtual COM mode (for bi-directional communication) using internal settings. For the latter, a driver (available for download here) needs to be installed on the PC (except for those with Windows 10).
Options*5*6
GXA-03 : 2nd RS-232C interface Manual (PDF 1.3 MB)
GXA-04 : Comparator relay output/buzzer/external key input interface Manual (PDF 1.3 MB)
GXA-06*7 : Analog (0-1/0.2-1 V) output interface Manual (PDF 1.3 MB)
FXi-08 : Ethernet (TCP/IP) interface Manual (PDF 134 KB)
GXA-09 : Built-in rechargeable battery (factory-installed/dealer option) Manual (PDF 266 KB)
GXA-10 : Large glass breeze break (standard for the 0.0001 g models of the GX-A/GF-A series) Manual (PDF 189 KB)
GXA-12 : Animal weighing pan (for the 0.001/0.01/0.1 g models of 320 g capacity or higher) Manual (PDF 184 KB)
GXA-13 : Density determination kit for the 0.001 g models Manual (PDF 801 KB)
GXA-14 : Density determination kit for the 0.0001 g models Manual (PDF 848 KB)
GXA-17 : Large glass breeze break with built-in fanless ionizer and external IR switch (standard for the GX-AE series) Manual (PDF 509 KB)
GXA-23-PRINT : External key input interface + the AX-SW137-PRINT foot switch Manual (PDF 300 KB)
GXA-23-REZERO : External key input interface + the AX-SW137-REZERO foot switch Manual (PDF 300 KB)
GXA-23-PLUG : External key input interface + the AX-T-314A-S plug Manual (PDF 300 KB)
GXA-24 : USB host interface (factory-installed/dealer option) Manual (PDF 364 KB)
GXA-25 : Fanless ionizer of Quick Ion® technology Manual (PDF 712 KB)
GXA-26 : External IR switch Manual (PDF 300 KB)
GXA-27*8 : Bluetooth® interface Manual (PDF 226 KB)
*5 Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-17, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25, GXA-26, or GXA-27 can be installed (meaning that GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, or GXA-27 cannot be installed in the GX-AE series without first removing its interface for the built-in fanless ionizer.).
*6 The GX-AWP/GF-AWP series are not IP65 with GXA-03, GXA-04, GXA-06, FXi-08, GXA-17, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25, or GXA-26.
*7 Analog output is updated according to the display refresh rate.
Display refresh rate can be changed in the internal settings of the balance.
(approx. 5/10/20 times/sec)
*8 Please contact your local A&D representative to find out whether GXA-27 is certified for compliance with Bluetooth® communication laws in your country.
Accessories
AD-1641 : Air flow logger AD-1682 : Rechargeable battery unit AD-1683 : Static eliminator*9 AD-1684A : Electrostatic field meter AD-1687 : Weighing environment logger AD-1688 : Weighing data logger AD-1689 : Tweezers for calibration weight AD-8127 : Compact printer AD-8526 : RS-232C/Ethernet (TCP/IP) converter AD-8529PC-W : Bluetooth® converter for PC AD-8529PR-W : Bluetooth® converter for printer AD-8920A : Remote display AD-8922A : Remote controller
AX-BM-NEEDLESET : Electrode unit for ionizer (4 pcs)
AX-GXA-31 : Main unit cover (5 pcs)
AX-KO2737-500 : Waterproof RS-232C cable (5 m)
AX-SW137-PRINT : Foot switch for print
AX-SW137-REZERO : Foot switch for re-zero AX-USB-9P : RS-232C/USB converter
*9 Power needs to be supplied from an AC adapter. Recommended when Apollo has another option than GXA-17 or GXA-25 installed.
Specifications
Models
GX-124AE GX-124A GF-124A
GX-224AE GX-224A GF-224A
GX-324AE GX-324A GF-324A
Capacity
122 g
220 g
320 g
Readability
0.0001 g
Repeatability (standard deviation)
0.0001 g
0.0002 g (300 g) 0.0001 g (200 g)
Minimum weight* (typical)
120 mg
Linearity
±0.0002 g
±0.0003 g
Stabilization time (when set to FAST under a good environment)
Approx. 1.5 sec (100 g)
Approx. 2 sec (200 g) Approx. 1.5 sec (100 g)
Approx. 2 sec (300 g) Approx. 1.5 sec (100 g)
Weighing pan size
Ø90 mm
External dimensions
259 (W) × 358 (D) × 332 (H) mm (including the large glass breeze break)
Net weight
Approx. 7 kg
Models
GF-123A
GX-203A GX-203AWP GF-203A GF-203AWP
GX-303A GF-303A
GX-403A GX-403AWP GF-403A GF-403AWP
GX-603A GX-603AWP GF-603A GF-603AWP
GX-1003A GF-1003A
GX-1603A GF-1603A
Capacity
122 g
220 g
320 g
420 g
620 g
1100 g
1620 g
Readability*
0.001 g
Repeatability (standard deviation)
0.001 g
0.002 g (1600 g) 0.001 g (1000 g)
Minimum weight** (typical)
GX-A/GF-A: 1.4 g | GX-AWP/GF-AWP: 1.8 g
Linearity
±0.002 g
±0.003 g
Stabilization time (when set to FAST under a good environment)
Approx. 1 sec Approx. 0.8 sec (5 g)
Approx. 1.5 sec Approx. 0.8 sec (5 g)
Weighing pan size
128 mm × 128 mm
External dimensions
GX-A/GF-A: 212 (W) × 317 (D) × 171 (H) mm (including the small plastic breeze break)
GX-AWP/GF-AWP: 212 (W) × 326 (D) × 171 (H) mm (including the small plastic breeze break)
Net weight
Approx. 5 kg
Models
GF-1202A
GX-2002A GX-2002AWP
GF-2002A GF-2002AWP
GX-3002A
GF-3002A
GX-4002A GX-4002AWP
GF-4002A GF-4002AWP
GX-6002A GX-6002AWP
GF-6002A GF-6002AWP
GX-10002A
GF-10002A
GX-6001A GX-6001AWP
GF-6001A GF-6001AWP
GX-10001A
GF-10001A
Capacity
1220 g
2200 g
3200 g
4200 g
6200 g
10200 g
6200 g
10200 g
Readability*
0.01 g
0.1 g
Repeatability (standard deviation)
0.01 g
0.02 g (10000 g) 0.01 g (5000 g)
0.1 g
Minimum weight** (typical)
GX-A/GF-A: 14 g | GX-AWP/GF-AWP: 18 g
100 g
Linearity
±0.02 g
±0.03 g
±0.1 g
Stabilization time (when set to FAST under a good environment)
Approx. 1 sec Approx. 0.8 sec (50 g)
Approx. 1.5 sec Approx. 0.8 sec (50 g)
Approx. 1 sec Approx. 0.8 sec (500 g)
Weighing pan size
165 mm × 165 mm
External dimensions
GX-A/GF-A: 212 (W) × 317 (D) × 93 (H) mm
GX-AWP/GF-AWP: 212 (W) × 326 (D) × 93 (H) mm
Net weight
Approx. 5 kg
* Repeatability can worsen depending on the environmental conditions and operator skills.
** Pursuant to the United States Pharmacopeia (USP), Chapter 41