Support
Software
Weighing and Laboratory Equipment
Freeware
WinCT WinCT-AD1687 WinCT-AD4212C WinCT-AD4212D WinCT-AD4212F WinCT-DLC WinCT-Plus WinCT-Counting WinCT-UFC WinCT4411 WinST WinCT-ParamSet WinCT-GXA-Filter WinCT-FRD Driver SoftwareWinCT
WinCT is software designed to import weighing data from A&D balances and scales to a computer. It allows data to be imported in text format or directly into a third party software application. Bidirectional communication is possible.
RsCom: Sends and receives data between the balance and the computer, useful for controlling the balance.
RsKey: Automatically inputs data outputted from the balance into other application software.
RsWeight: Graphs data received from the balance in real-time. Also calculates and displays metrics such as maximum value, minimum value, average, standard deviation, coefficient of variation, etc.
More details
Guide to WinCT Software and How to Check PC COM Ports (PDF 141KB)
For Windows Vista or later versions, please use WinCT 6.02
DOWNLOAD WINCT 6.02
Instruction manual (PDF 1.2MB)
Setup manual (PDF 236KB)
For Windows XP or earlier versions, please use WinCT 3.00
DOWNLOAD WINCT 3.00
Setup manual (PDF 39KB)
WinCT-AD1687
WinCT-AD1687 is software for graphing measurement environment data saved in the AD-1687 using Excel. AD-1687 Setting Tool is software for changing the internal settings of the AD-1687.
More details
AD-1687 Setting Tool
DOWNLOAD AD-1687 SETTING TOOL
Instruction manual (PDF 734KB)
WinCT-AD-1687
DOWNLOAD WINCT-AD-1687 (for Excel 2000-2003)
DOWNLOAD WINCT-AD-1687 (for Excel 2007-2010)
Instruction manual (PDF 535KB)
WinCT-AD4212C
WinCT-AD4212C is data communication software that allows sensitivity adjustment of the AD-4212C, adjustment of measurement speed, internal filtering, zero tracking, and averaging settings. Compatible with Windows XP or later, it can be used on both 32-bit and 64-bit systems.
DOWNLOAD WINCT-4212C
Instructions for WinCT-AD4212C (in the AD-4212C Instruction Manual) (PDF 2.5MB)
Supplement to Manual for WinCT-AD4212C (PDF 245KB)
WinCT-AD4212D
With the WinCT-AD4212D software, it is possible to display the weighing value and change the internal settings of the balance on your PC.
DOWNLOAD WINCT-4212D
Instruction manual (PDF 305KB)
WinCT-AD4212F
WinCT-AD4212F is software that enables the acquisition of weighing data, customization of internal settings such as the balance's response characteristics, and the output of results from the self-check function (using ECL) and Impact Shock Detection (ISD).
Compatible OS: Windows
• Simulation of weighing speed through changes in response characteristics, stability detection range, digital filter, etc.
• Switching of minimum display digits
• Sensitivity adjustment / changing weight value
• Execution of the self-check function (ECL) and data output
• Output of data recorded by the Impact Shock Detection (ISD)
• Power On/Off
DOWNLOAD WINCT-AD4212F
Instructions for WinCT-AD4212F (in the AD-4212F Instruction Manual) (PDF 5.1MB)
WinCT-DLC
WinCT-DLC is program software designed exclusively for the USB-compatible digital load cell series to import measurement data into a computer. It allows conversion of measurement results into CSV or Excel data formats.
System Requirements: Compatible with OS Windows 7/8.1/10 (64-bit), requires 4 GB or more memory, 20 GB or more hard disk space, and installation of .NET Framework 4.5 or higher.
* It can operate on 32-bit systems but is beyond the scope of guaranteed functionality.
* When extracting the downloaded zip file, access might be blocked. Right-click the zip file, open Properties, go to the General tab, and click 'Unblock' under Security. Then, attempt extraction again.
DOWNLOAD WINCT-DLC
Instruction manual (PDF 1.2MB)
WinCT-Plus
WinCT-Plus enables data collection from multiple weighing instruments on a single computer by directly connecting to multiple RS232C ports or through an RS232C-to-Ethernet converter for LAN connection. It allows simultaneous use of RS232C port and LAN connection.
More details
DOWNLOAD WINCT-PLUS
Manual for the AD8526 (PDF 1.6MB)
Manual for the OP-08 (PDF 1.5MB)
LAN connection settings require 'DeviceInstaller' and 'Com Port Redirector' for configuration changes.
DeviceInstaller is required to set the IP address and other configuration information of A&D balances and scales.
32 bit compatible >
https://ts.lantronix.com/ftp/DeviceInstaller/Lantronix/4.4/4.4.0.7/Installers/Download_Web/DI_x86DL_4.4.0.7.msi
64 bit compatible >
https://ts.lantronix.com/ftp/DeviceInstaller/Lantronix/4.4/4.4.0.7/Installers/Download_Web/DI_x64DL_4.4.0.7.msi
Com Port Redirector enables virtual serial communication from A&D balances and scales connected to an Ethernet network (Virtual COM port). With the virtual COM port connection, serial communication software such as RsCom or your original serial communication software can be used directly.
Windows XP, Vista, 7 (32bit) CPR_x86DL_4.3.0.3.msi> https://ts.lantronix.com/ftp/cpr/Lantronix/4.3/4.3.0.3/Installers/Download_Web/CPR_x86DL_4.3.0.3.msi
Windows Vista, 7, 8.1, 10 (64bit) CPR_x64DL_4.3.0.3.msi> https://ts.lantronix.com/ftp/cpr/Lantronix/4.3/4.3.0.3/Installers/Download_Web/CPR_x64DL_4.3.0.3.msi
WinCT-Counting
WinCT-Counting enables product registration via PC, significantly enhancing the efficiency of the registration process.
Supported OS: Windows
More details
DOWNLOAD WINCT-COUNTING
Instruction manual (PDF 4.2MB)
Setup manual (PDF 180KB)
WinCT-UFC
WinCT-UFC is software that allows editing the 'UFC output format' of A&D scales equipped with UFC function on a PC.
* Not compatible with Windows Vista
More details
For Windows 7 or later versions, please use WinCT-UFC Ver.2.20
DOWNLOAD WINCT-UFC VER.2.20
For Windows XP or earlier versions, please use WinCT-UFC Ver.1.00
DOWNLOAD WINCT-UFC VER.1.00
Instruction manual (PDF 1.4MB)
Setup manual (PDF 341KB)
WinCT4411
WinCT4411 is Windows application software for modifying, backing up, copying internal settings, and logging measurement data for the AD-4411 series on a PC.
Operating environment: Microsoft® Windows® 10/11 .NET Framework 7.4.2.
DOWNLOAD WINCT4411
Instruction manual (PDF 369KB)
WinST
WinST is software used to save various settings of the AD-4402 in text format on a PC, and to write files saved on the PC to the AD-4402.
More details
DOWNLOAD WINST
WinCT-ParamSet
WinCT-ParamSet is software that allows you to modify the internal settings of the balance from a PC. Compatible models include GX-A/GF-A, FZ-i/FX-i, GX-M/GF-M. An additional cable to connect the PC and the balance is required (e.g. USB conversion cable AX-USB-9P)
More details
DOWNLOAD WINCT-PARAMSET
Instruction manual (PDF 1MB)
Setup manual (PDF 164KB)
WinCT-GXA-Filter
This software is for users who wish to install the GX-A/GF-A balance in an automated weighing system and adjust its response settings beyond the standard settings.
(Supported balance software versions: 1.4000 or later)
DOWNLOAD GXA-FILTER
Instruction manual (PDF 1.4MB)
Setup manual (PDF 206KB)
WinCT-FRD
This software can produce a graph in real-time from the data transmitted from A&D GX-A/GF-A series balances with the flow measurement function.
More details
DOWNLOAD WINCT-FRD
Instruction manual (PDF 348KB)
Setup manual (PDF 190KB)
Driver Software
- Driver software for HVW-02CB (USB interface option for the HV/W-C(P) and HV/W-CWP series)
Download - Virtual COM mode driver software for the GX-A/GF-A series USB interface
Download - Driver software for the AD-8529PC-W (Bluetooth converter for PC)
Download - The LabVIEW Driver® for A&D Balances
- Driver software for the AD-8541-PC (Wireless Communication Interface for PC)
Download - Driver software for AX-USB-25P / AX-USB-9P / AX-USB-DIN (USB Converter and Cable Set)
Download
Related Information
- Supported OS Versions for Windows Communication Tools Software (as of February 05, 2018) (PDF 91KB)
- Windows 11 Supported Versions of Communication Tools Software (as of November 29, 2023) (PDF 46KB)
- Windows 10 Supported Versions of Communication Tools Software (as of November 29, 2023) (PDF 52KB)
- Models that can be connected to Mac via USB (WinCT is not supported) (PDF 86KB)
- WinCT-Moisture for Moisture Analyzers (Standard with MS-70 and MX-50)
- WinCT-Viscosity for Viscometers (Standard with the SV-A/SV Series)
Healthcare Analysis Software
- BP Diary (Free Software)
- Weight Diary for UC-322/321/322P (Free Software)
- Weight Diary Chart download (PDF)
- Doctor Pro for TM-2430/UA-767PC (Application Software)
- Monitor Pro for UA-767PC (Application Software)