Product

Weighing

  • Balances
  • Scales
  • Indicators
  • Loadcells
  • Peripherals
  • Software
LC-4102 (Aluminum)
For small and medium capacity weighing system,single point compact load cells
LC-4102
Capacity Model No. CAD file
10 kgf LC4102-K010 CAD Download
15 kgf LC4102-K015
30 kgf LC4102-K030
60 kgf LC4102-K060
150 kgf LC4102-K150
Download 3D CAD
PDFSetup Manual (PDF 323KB)
Please send your inquiry here
Features
Parallelogram-type construction
Temperature compensation maintains both zero and span from -10 °C to +40 °C (+14 °F to +104 °F)
Deadweight up to 80 % of capacity. Load weight and deadweight up to 180% of capacity
Moisture proof
Compact and lightweight
Specifications
Rated capacities ..........................10 kgf, 15 kgf, 30 kgf, 60 kgf, 150 kgf
Rated output .................................1 mV/V+15/-0%
Maximum deadweight ................80% of rated capacity
Maximum safe overload .............300% of rated capacity
Combined error ...........................±0.015% of rated output
Creep .............................................±0.05% of rated output/hour
Zero balance ................................20±5% of rated output
Compensated
temperature range .....................-10 °C to +40 °C/+14 °F to +104 °F
Recommended
excitation voltage ........................12 V
Maximum
excitation voltage .......................15 V
Input terminal resistance .........Approximately 400 Ω
Output terminal resistance......350 Ω ± 5 Ω
Insulation resistance ...............Greater than 5000 MΩ at DC50 V
Temperature effect
Zero .............................................0.004% of rated output/°C
Span ...........................................0.0014% of rated output/°C Typ.
Platform size .............................400 × 400 mm/15.8 ×15.8 inches
Cable length .............................1.5 m/59 inches
  Drawing
Related Content

Load Cells Q&A

Introduction to Load Cells

Measurement Knowledge

For those who are new to load cells”. Let's learn together what a load cell is. More detailed materials than the “Load Cells Q&A”. Technical information on indicators and load cells.